R2Z-6400P Redundant 2U 400W EPS Emacs Zippy.
400W for Server, Workstation, Storage System, IPC, Communication,
Networking.
265.00 x 101.00 x 84.00 (mm) 10.43x3.98x3.31 (inch).
90 ~ 264 VAC FULL RANGE
Output Voltage |
Output Current Min. |
Output Current Max. |
Output Current Peak |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
5V |
3 |
25.00 |
|
± 5% |
± 1% |
50mV |
12V |
2 |
28 |
|
± 7% |
± 1% |
100mV |
-5V |
0.1 |
0.50 |
|
± 10% |
± 1% |
150mV |
-12V |
0.1 |
0.80 |
|
± 10% |
± 1% |
150mV |
3.3V |
1 |
20 |
|
± 5% |
± 1% |
50mV |
+5VSB |
0.1 |
2 |
|
± 5% |
± 1% |
50mV |
1.TOTAL POWER OF +5V AND + 3.3V NOT EXCEED 175W 2.TOTAL +5V AND 3.3V AND 12V POWER NOT EXCEED 384 W |
*TEMPERATURE RANGE : OPERATING 0℃ --- 40℃, STORAGE –20℃ --- 70℃ * HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95% * REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS *EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B *SAFETY: MEET UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950 *REMOTE ON / OFF CONTROL *FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL *HOT-SWAPPABLE / HOT-PLUGGABLE 1 + 1 REDUNDANCY FUNCTION *BALANCE LOAD SHARING DESIGN *ISOLATION: BUILT-IN IN THE POWER MODULE *MEET IEC-1000-3-2 CLASS D ( ACTIVE PFC ) *COOLING : TWO 38 mm DC FANS IN EACH MODULE | |