PIZ1040S-90-ACB 1U Flex ATX 400W 80 Plus Gold. Dimensions (D x W x H) 165 x 81.5x 40.5mm Efficiency The minimum efficiency of power supply should be over than 87% under the maximum and 20% load and should be over 90% under the half load. Load measurements are performed at 115VAC/230Vac input. The PF should be over than 0.9 under 20% load at 115VAC. It is better to meet the 80 plus requirement .as the web site as follow: http://www.80plus.org/ Environrmental Specificatios 8-1. Operating Temperature Range Operation ambient : 0 ℃ to + 50℃ Non-operating ambient : -40℃ ~ +70℃ 8-2. Thermal Shock (Shipping) Non-operating : -40 ~ 70℃ (15℃/min≦dT/dt≦30℃/min) 8-3. Altitude Operating To 5000 m Non-operating To 15,000 m 8-4. Random Vibration Sine sweep, 5 Hz~200 Hz , 1g. Sweep rate : 1 Oct/Min, three axes. Dwell natural frequency,2G , per point 15 minutes.(non-operating) 8-5. MTBF and Cap Life 100,000 Hours “80% Load at 25℃,115V / 60Hz or 230V / 50Hz” for MTBF. 26,280 Hours “80% Load at 25℃,115V / 60Hz or 230V / 50Hz” for Capacitor life. 8-6. Mechanical Shock Sqare wave ,50G ; velocity 167 in/s per face three times. (non-operating)
Input Specifications 1-1. Input condition:
Range Select
|
Nominal
|
Units
|
Vin
|
100 - 240
|
VAC
|
Frequency
|
50 - 60
|
Hz
|
AC input current
|
6A / 115VAC 3A / 230VAC
|
AMPS
|
1-2. Inrush Current Maximum inrush current from power-on (with power on at any point on the AC sine) shall be limited to the peak surge current of the input line cord, bridge diode, fuse and EMI filter components according to I2t. Receptive ON/OFF cycling of the AC input voltage shall not damage the PSU or cause the input fuse to blow.
Output Specifications Output Voltage and Ripple Noise Requirements
Output Voltage
|
MIN
|
MAX
|
Regulation (%)
|
Ripple Max
|
+5V
|
4.75
|
5.25
|
+5% ~ -5%
|
50mV
|
+3.3V
|
+3.3
|
3.465
|
+5% ~ -5%
|
50mV
|
+12V
|
11.4
|
12.6
|
+5% ~ -5%
|
120mV
|
+5Vs
|
4.75
|
5.25
|
+5% ~ -5%
|
50mV
|
-12V
|
10.8
|
13.2
|
+10% ~ -10%
|
120mV
|
Note: 1). The output voltage should be measured at output connector terminals. 2). The output Ripple Noise should be tested with 10 F of tantalum and 0.1 F ceramic disk capacitors to simulate system loading. Safety The power supply will have the following safety approvals with most current editions shipping: 9-1. UL/CAN/CSA 9-2. TUV/EN 9-3. IEC/CB 9-4. CE 9-5. FCC 9-6. BSMI 9-7. CCC
|