R2G-5800V PIZ1081-C3EG-PMBUS IPS Redundant 800W. R2G-5800V4V Power system is a 1+1 Redundant power system consisting of two GIN-3800V power modules and one power system frame. Idea for 2U/3U rackmount chassis . High Efficiency:>84% (230V). Featured with PMBUS. 2U/3U Industrial Redundant PSU 800Wx2 80+ Silver with Pmbus Dimension:(W)X(H)x(L)101x82x340mm
Input requirements >Voltage (sinusoidal) Full Range : 100 - 240 VAC (With ± 10% tolerance) >Frequency : The input frequency range will be 50Hz/60Hz(±3Hz). >Steady-state current : 12.0 - 6.0 amps maximum at any low/high range input voltage. >Inrush current ; 60 / 80 amps @115/230 VAC (at 25 degrees ambient cold start for each power unit) >Power factor correction ; The power supply modules shall incorporate universal power input with active power factor correction, which shall reduce line harmonics in accordance with the EN 61000-3-2 standards. PFC can reach the target of 95% @230V,full load. Output requirements >DC load requirements
Normal Load Current Regulation tolerance Output Voltage Max Min Max Min 5V 32.0 0.5 +5% -5% 12V 65.0 2.0 +5% -5% -12V 0.8 0.0 +10% -10% +3.3V 32.0 0.5 +5% -5% +5VSB 3.5 0.1 +5% -5% *** +5V and+3.3V total output max : 190W *** *** Total output max : 800W ***
When doing the cross regulation test(one output channel at high load and the other output channels at low load), it is requested to set the higher output channel at 80% max. of its spec., and the lower output channels at 20% max. of theirs. Protection Input (primary): The input power line must have an over power protection device in accordance with safety requirement of section 8.0 Output (secondary): Over power protection (one unit) The power supply shall provide over power protection on the power supply latches all DC output into a shutdown state. Over power of this type shall cause no damage to power supply,after over load is removed and a power on/off cycle is initiated,the power supply will restart. Trip point total power min. 110%,max. 160%. Over voltage protection : If an over voltage fault occurs,the power supply will latch all DC output into a shutdown state before +5V :5.9V ∼ 6.7V +3.3V :3.9V ∼ 4.3V +12V :13.0V ∼ 15.0V Safety 8.1 Recognized to U.S. and Canadian requirements under the component
recognition program of Underwriters Laboratories Inc. The power supply shall be designed to meet UL60950. 8.2 TUV Standards : The power supply shall be designed to meet TUV EN-60950. 8.3 CB The power supply shall be designed to meet CB IEC 60950.
Reliability 9.1 Burn in All products shipped to customer must be processed by burn-in. The burn- in shall be performed for 1 hour at full load.
|