> Input Ratings: - Input Voltage:100~240VAC +/-10% / 47 ~ 63Hz - Input Current:4.0A(RMS) for 115VAC, 2.0A(RMS) for 230VAC. - Inrush Current:35A Max. for 115VAC Per Module, 70A Max. for 230VAC Per Module
OUTPUT
Output Voltage |
Min. load |
Max. load |
Regulation LOAD LINE |
Output Ripple & Noise Max.(p-p) |
+5V |
1A |
20A |
5% |
1% |
60mV |
+3.3V |
1A |
20A |
5% |
1% |
60mV |
+12V |
2A |
32A |
5% |
1% |
120mV |
-12V |
0A |
0.5A |
5% |
1% |
120mV |
+5VSB |
0.5A |
3A |
5% |
1% |
60mV |
▪ Hold up Time: 1m sec Min. AT Full Load. ▪ Rated Power: +5V&+3.3V TOTAL OUTPUT MAX.:150W;
Power module Total output power not exceed 400W
INPUT ▪ VOLTAGE RANGE/FREQUENCY: 100~240VAC +/-10% / 47 ~ 63Hz ▪ CURRENT: 7.0A(RMS) for 115VAC, 3.0A(RMS) for 230VAC. ▪ EFFICIENCY(Typ.): >80% at full load. ▪ INRUSH CURRENT: 35A Max. for 115VAC Per Module, 70A Max. for 230VAC Per Module
PROTECTION ▪ OVER LOAD: 110% ~ 150% MAX. ▪ OVER VOLTAGE: +3.3V→3.7V~4.1V ,+5V→5.7V~6.5V,+12V→13.2V~14.4V ▪ SHORT CIRCUIT: Shutdown And Latch Re-power ON ▪ Thermal Protection: The power supply shall go into thermal protection as the case temperature exceeds 86℃(±5℃)limit. The output shall recover only when the temperature becomes normal and AC power is turned on again
Buzzer status ▪ No AC power to all PSU: Buzzer status=OFF ▪ AC present/Only Standby Output On: Buzzer status=OFF ▪ Power supply DC outputs ON and OK: Buzzer status=OFF ▪ Power supply failure: Buzzer status= Beeping
LED indicators ▪ No AC power to all PSU: Power system status :RED=OFF, GREEN=OFF. Per Power Module status: ORANGE=OFF ▪ AC present/Only Standby Output On: Power system status :RED=ON, GREEN=OFF. Per Power Module status: ORANGE=OFF ▪ Power supply DC outputs ON and OK: Power system status :RED=OFF, GREEN=ON. Per Power Module status: ORANGE=ON ▪ Power supply failure: Power system status :RED=OFF, GREEN= Blinking. Per Power Module status: ORANGE=OFF
FUNCTION ▪ POWER GOOD SIGNAL: Delay 200ms~500ms, TTL compatible signal ▪ POWER FAIL DELAY: >1msec. ,TTL compatible signal ▪ PS-ON (REMOTE ON/OFF): Power off: PS-ON = 2V min.; Power on: PS-ON = 0.8V max. ▪ TTL signal: NORMAL(POWER SUPPLY ON):OUTPUT CONDITION =3V Min. , 5.25VMax. FAILURE(POWER SUPPLY OFF): OUTPUT CONDITION =0V Min. ,1VMax. ▪ CURRENT SHARING: ON +3.3V,+5V,+12V
SAFETY ▪ SAFETY STANDARDS: TO MEET CUL UL, TUV ▪ WITHSTAND VOLTAGE: I/P-O/P:1.5KVAC FOR 1 minute. I/P-FG:1.5KVAC FOR 1 minute ▪ ISOLATION RESISTANCE: I/P-O/P,I/P-FG,O/P-FG: 500VDC , 50M ohms min.
EMC ▪ EMI CONDUCTION: Compliance CISPR22 Class A, FCC Class A
ENVIRONMENT ▪ OPERATING TEMPERATURE: 0℃ to +45℃ ▪ STORAGE TEMPERATURE: -20℃ to +70℃ ▪ OPERATING HUMIDITY: 20% to 90%,non-condensing ▪ STORAGE HUMIDITY: 5% to 95%, non-condensing
OTHERS ▪ MTBF: Using MIL - HDBK -217F the calculated MTBF>100,000 hours at 25℃ ▪ COOLINGS: 40x40x20mm x 2pcs DC fans ▪ DIMENSION: 260(D)X106(W)x41.5(H)mm
▪ 1U Size Design ▪ Hot-Swappable & Power Sharing capability ▪ Full Range AC input ▪ Low Ripple Noise ▪ High Power Density ▪ High Performance industrial Fan ▪ High Reliablity |