- Thermal Protection -
▪ The power supply shall go into thermal protection as the case temperature exceeds 86ºC(±5ºC)limit.
▪ The output shall recover only when the temperature becomes normal and AC power is turned on again
▪ Protections
Over Power: 110% ~ 150% MAX.
Over Voltage: +3.3V→3.7V~4.1V ,+5V→5.7V~6.5V,+12V→13.2V~14.4V
Short Circuit: Shutdown And Latch Re-power ON
▪ Function
Power Good Signal: Delay 200ms~500ms, TTL compatible signal
Power Fail Delay: >1msec. ,TTL compatible signal
PS-ON: Power off: PS-ON = 2V min.; Power on: PS-ON = 0.8V max.
TTL Signal: Normal(Power Supply On): Output Condition =3V Min. , 5.25VMax.
Failure(Power Supply Off): Output Condition =0V Min. ,1VMax.
Current Sharing: ON +3.3V,+5V,+12V
▪ Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to +80°C
Operating Humidity: 20% to 90%,non-condensing
Storage Humidity: 5% to 95%,non-condensing
▪ Safety & EMI/RFI
Safety Standards: TO MEET CUL UL, TUV
Withstand Voltage: I/P-O/P:1.5KVAC FOR 1 minute. I/P-FG:1.5KVAC For 1 minute
Isolation Resistance: I/P-O/P,I/P-FG,O/P-FG: 500VDC , 50M ohms min.
▪ Others
MTBF: Using MIL - HDBK -217F the calculated MTBF >100,000 hours at 25°C
Coolings: 40x40x20mm x 2pcs DC fans
Dimension(D x W x H): 260(D)X106(W)x41.5(H)mm
Output Voltage |
Min. load |
Max. load |
Regulation LOAD LINE |
Output Ripple & Noise Max.(p-p) |
+5V |
1A |
20A |
5% |
1% |
60mV |
+3.3V |
1A |
20A |
5% |
1% |
60mV |
+12V |
2A |
24A |
5% |
1% |
120mV |
-12V |
0A |
0.5A |
5% |
1% |
120mV |
+5VSB |
0.5A |
2A |
5% |
1% |
60mV |
▪ Efficiency: 75% Typical at full load.
▪ Hold up Time: 1m sec Min. AT Full Load.
▪ Rated Power: 1.+5V&+3.3V TOTAL OUTPUT MAX.:150W;
2.Power module Total output power not exceed 300W
20+4 Pin |
P4 MB |
Peripheral |
FDD |
8-Pin |
SATA |
X 1 |
X 1 |
X 5 |
X 1 |
X 1 |
X 3 |